This unit includes two passes of primary heat exchanger capable of achieving 65% thermal efficiency. The first pass of the heat exchanger is relatively new and is upgraded from Type 316 stainless steel to Type 310 stainless steel. The burner is a APCO air cooled burner capable of operating at elevated temperatures. The oxidizer includes a high temperature heat exchanger bypass and if purchased refurbished includes a new control panel and gas train.
 
20,000 scfm
65% efficient, two pass primary heat exchanger 
Upgraded first pass heat exchanger tube bundle using Type 310 stainless steel
95-99% destruction efficiency - higher efficiency requires increased dwell time and modified tube bundles
Supply fan including 200 Hp, TEFC motor
Vertical configuration
Superior housing construction using fully welded, steel plate exterior skin with internal, nonasbestos, high temperature insulation
New control panel and gas train with refurbished unit, original control panel and gas train with as is purchase.
   
For more information:

Telephone: 800-388-8301 (in USA or Canada only)
or 973-402-8301
Fax: 973-402-8302

251 Boulevard, Mountain Lakes, NJ 07046-1209

Electronic Mail Equipment Information: ciretech@optonline.net

 